Natural Gas Heating Value Calculator
Calculate gross and net heating value of natural gas from composition. Essential for gas sales contracts, flare calculations, and combustion engineering.
Inputs
Results
Gross HHV
--
BTU/scf
Net LHV
--
BTU/scf
Gas Specific Gravity
--
(air=1)
Molecular Weight
--
lb/lb-mol
Equations
Heating value: HHV = Σ(y_i × HHV_i) where HHV_i is pure component gross heating value
Component HHVs (BTU/scf): CH₄=1012, C₂H₆=1769, C₃H₈=2516, i-C₄=3252, n-C₄=3262, N₂=0
LHV ≈ HHV - 50.3 × H₂O_formed_per_scf
Molecular weight: MW = Σ(y_i × MW_i), air MW = 28.97; SG = MW/28.97
Need gas quality analysis, BTU measurement, or gas sales contract support?